Portable pH Meter
PH-30
The PH30 Series Portable pH Meters are high-performance instruments designed for accurate pH measurement across diverse fields, including:
Environmental Science: Acid rain detection, industrial wastewater, surface water, and drinking water analysis.
Food & Beverage: pH monitoring in beverages, dairy products, and processed foods.
Healthcare: Pharmaceutical R&D, cosmetics, and textile quality control.
Industrial & Academic: Metallurgy, geological exploration, and marine research.
- Description
- Accessories
-
- Brand: WATENV
- Commodity name: Portable pH Meter
- 系列: PH-30
Features
Equipped with an LCD display that presents all data on a single screen. Features a user-friendly interface with button-operated settings, ensuring clear visibility and intuitive operation.
Complies with IP65 protection rating through sealed enclosure design, effectively preventing liquid ingress that could corrode internal circuits and ensuring operational safety.
Supports data storage, deletion, and review functions for comprehensive record management.
Incorporates parameter memory function to automatically recall previous settings upon repowering, streamlining operational procedures. Features power-off protection and factory reset functionality.
Enables automatic recognition of three pH calibration buffers (GB4.00, 6.86, 9.18). Supports electrode calibration with up to 3-point calibration (PH30-3/4 Models).
Offers dual measurement modes: Continuous Measurement and Stable Measurement (PH30-3/4 Models).
Provides both manual and automatic temperature compensation options (PH30-3/4 Models).
Supports data printing and PC connectivity for data export (PH30-3/4 Models).
Technical Parameters
Model PH-30-1 PH-30-2 PH-30-3 PH-30-4 Power Supply Input AC 100~240V-50~60Hz 0.35A;Output DC 5V/2A Accuracy Class 0.1 0.02 0.01 0.001 Screen size 4 inches 4 inches 4 inches 4 inches mV Range -1400.0~1400.0 -2000.0~
2000.0
-2000.0~
2000.0
-2000.0~
2000.0
Resolution 1 0.1 0.1 0.01 Accuracy ±0.2%FS ±0.1 % FS ±0.1 % FS ±0.03 % FS pH Range 0.00~14.00 -2.00~18.00 -2.00~18.00 -2.00~20.00 Resolution 0.01 0.01 0.01 0.0 0 1 Accuracy ±0.05 ±0.01 ±0.01 ±0.002 Auto-Buffer
Recognition
NIST 4.00, 6.86, 9.18 4.00, 6.86, 9.18 4.00, 6.86, 9.18 4.00, 6.86, 9.18 USA 4.01, 7.00, 10.01 4.01, 7.00, 10.01 4.01, 7.00, 10.01 4.01, 7.00, 10.01 EURO 4.01, 7.01, 9.21 4.01, 7.01, 9.21 4.01, 7.01, 9.21 4.01, 7.01, 9.21 Temperature Compensation Manual Manual Manual/Automatic Manual/Automatic Calibration Points 2 2 3 3 Measurement Mode Continuous Continuous Continuous/
Stable
Continuous/
Stable
Data Storage 200 sets 200 sets 500 sets 1000 sets Electrode Interface Q9 Q9 Q9 Q9 Protection Rating IP65 IP65 IP65 IP65 Net weight 450g 450g 450g 450g Dimensions(L*W*H) 202.4*112*61mm 202.4*112*61mm 202.4*112*61mm 202.4*112*61mm -
pH Electrode
Combination
pH Electrode
Glass
ORP Electrode Conductivity Electrode Temperature Electrode pH Electrode Combination
E-201-C
E-301-C
pH Measurement range
0~14ph
0~14ph
Junction Type
Single Salt Bridge
Single Salt Bridge
Reference System
Ag/AgCl
Ag/AgCl
Reference Junction Type
Non-refillable
Non-refillable
Connector Type
BNC (Q9)
BNC (Q9)
Cable Length
1 meter
1 meter
Operating Temperature
5~60℃
5~60℃
Electrode Storage Solution
3 mol/L KCl
3 mol/L KCl
Sensing Membrane
Spherical glass bulb
Spherical glass bulb
Combination
Reference + sensing
Reference + sensing + temperature probe
Temperature Electrode
/
2.5mm audio jack connector
Dimensions
12mm*160mm
12mm*160mm
Weight
0.060kg
0.078kg
pH Electrode Glass
6502
6503
pH Measurement Range
2–12
0–14
Junction Type
Ceramic
Ceramic
Electrode Body Material
Glass
Glass
Reference System
Ag/AgCl
Ag/AgCl
Reference Junction Type
Double junction, Refillable
Double junction, Refillable
Connector Type
Q9
Q9
Cable Length
1 meter
1 meter
Operating Temperature
5–90°C
5–90°C
Electrode Storage Solution
3 mol/L KCl
3 mol/L KCl
Sensing Membrane
Spherical glass bulb
Spherical glass bulb
Combination
Reference + sensing
Reference + sensing
Dimensions
φ12 × 165 mm
φ12 × 165 mm
Weight
0.1 kg
0.1 kg
Electrode Selection Guide
pH Electrode Glass
6502
6503
General Laboratory Use
Y
Y
Strong Acids/Bases or High-Corrosion Environments
×
Y
Low-Conductivity Solutions
Y
×
Pure Water
Y
×
Biochemical samples
×
×
Tris-containing solutions
×
×
Soil Water, Wastewater
×
Y
Viscous, Emulsion, or Oily Substances (emulsions, food products, cosmetics, pigments, paints)
×
Y
(Note: Y = Suitable, × = Unsuitable)
ORP Electrode
5001
Body Material
Plastic
Sensor Design
Needle-Type PlatinumTip
Reference System
Plastic Fiber, Single Junction, Non-Refillable
Connector Type
Q9
Cable Length
1 Meter
Operating Temperature
5–60°C
Electrode Storage Solution
3mol/L KCl Solution
Electrode Features
General-Purpose
Dimensions
Φ12×160mm
Weight
0.1kg
Conductivity Electrode
DJS-0.1
DJS-1 (Platinum Black)
DJS-10 (Platinum Black)
Application
Ultra-pure water, pure water
Environmental water, routine water
High-electrolyte solutions
Housing Material
Glass
Glass
Glass
Cell Constant (K)
0.1±0.02
1±0.2
10±2
Measurement Range
0.055~300µS/cm
50~2000µS/cm
2~100mS/cm
Dimensions (mm)
φ12×155
φ12×155
φ12×155
Weight (kg)
0.1
0.1
0.1
Temperature Electrode
T-10K
Material
Stainless steel
Temperature Coefficient
10K
Measurement Range
0-100℃
Dimensions
φ12×155 mm
Weight
0.1kg